fleet-health-report

bởi nvidia

Tạo ảnh chụp nhanh HTML về tình trạng toàn bộ hạm đội độc lập từ dữ liệu nvfleetint trực tiếp, bao gồm tình trạng nút, dung lượng, tác động cảnh báo đang hoạt động, lỗi gần đây và…

npx skills add https://github.com/nvidia/fleet-intelligence-client --skill fleet-health-report

Fleet Health Report

Generate one offline HTML snapshot from fresh nvfleetint JSON. Read the CLI contract, HTML theme, and workspace guide before collecting data.

Workflow

1. Resolve and verify the profile

Resolve credentials before any report query:

nvfleetint auth list --output json
nvfleetint auth status --profile <profile> --output json

Use the user-named profile or the sole configured profile. If multiple profiles exist and none was requested, ask which one to use and identify the current one as the default suggestion. Require connection equal to ok, then pass the same explicit --profile <profile> to every API-backed command below.

2. Collect overview

Collect the tenant overview before inventory:

nvfleetint overview --profile <profile> --output json

Use it for the entire-fleet headline. In a scoped report, label it fleet-wide context and derive scoped totals from the filtered node list instead.

3. Collect inventory and resolve scope

Accept the entire fleet, compute-zone names, or node-group names. List compute zones first, node groups second, and nodes third. Resolve supplied names to IDs internally; clarify only ambiguous name matches.

Probe each list with the same filters, --view basic where supported, and --page-size 1 before its full pull. Collect the full lists in this order:

nvfleetint computezone list --all --profile <profile> --output json
nvfleetint nodegroup list --all --profile <profile> --output json
nvfleetint node list <scope> --data-source inband --all --profile <profile> --output json

After the first two lists, apply resolved --compute-zone-ids or --nodegroup-ids to the node query.

4. Collect recent errors

Pin one 24-hour error window. Use GNU date -u -d "@$now" and date -u -d "@$((now - 86400))", or BSD/macOS date -u -r "$now" and date -u -r "$now" -v-24H, formatted as RFC3339 UTC.

nvfleetint report error --view list --group-by error \
  --start "$start" --end "$end" --all \
  --profile <profile> --output json

Sum row count; pagination total counts grouped rows, not error occurrences. The error API cannot filter by zone/group, so label it tenant-wide in a scoped report or omit it when strictly scoped evidence is required.

5. Collect filtered active alerts

Discover the server-supported filter values first:

nvfleetint alert options --view active --profile <profile> --output json

From the returned componentTypes options, build a comma-separated list of component IDs excluding exact IDs psirt and agent_liveness. Stop if no component IDs remain.

Request the filtered count of all affected nodes and up to 10 machines ordered by active-alert count:

nvfleetint alert summary <scope> --view active \
  --component-type <component-types> \
  --sort-by alert --order desc --page-size 10 \
  --profile <profile> --output json

Use summary .total for all Nodes with Active Alerts and .totalCritical/.totalWarning for filtered fleet-wide severity totals. The bounded page contains up to 10 machines ordered by active-alert count; state showing N of total when applicable. Do not fetch every affected node merely to count or rank them.

For each returned UUID only, fetch its full filtered drill-down:

nvfleetint alert node <node_uuid> --view active \
  --component-type <component-types> --all \
  --profile <profile> --output json

Run at most four node calls concurrently. Alert collection invokes at most 12 nvfleetint commands: one options command, one summary command, and up to 10 node commands. An --all command may make multiple paginated requests.

6. Derive and write the report

  • Entire fleet: show overview.healthPercentage once as Fleet Health Percentage. Scoped: show 100 * healthy / total once as Healthy Node Percentage and its formula. Do not show both or repeat the percentage in Fleet Summary.
  • Keep node health/severity at source level; present fleet counts and distributions without an aggregate fleet severity badge.
  • Join the returned summary machines to inventory by UUID and preserve the returned order.
  • Use node-alert rows only for those machines' drill-down detail; do not infer unseen component distribution.

Apply the shared HTML theme and use these four report sections:

  1. Fleet Summary: executive summary, fleet totals, and health distribution.
  2. Fleet Distribution: compute zones, node groups, capacity, and operational signals.
  3. Active Alerts: filtered Nodes with Active Alerts, severity aggregates, Machines Needing Immediate Attention (up to 10), and one expandable per-machine drill-down showing component, status, start time, last update, and available evidence text.
  4. Error Distribution: grouped recent errors over the pinned window.

7. Validate and deliver

Apply the CLI contract's completeness checks. The bounded summary page is the only intentional partial result; use its top-level aggregates for fleet-wide claims. For an entire-fleet report, reconcile overview totals with complete inventory totals.

Validate the final HTML:

for id in at-a-glance distribution alerts errors; do
  grep -q "id=\"$id\"" "$out" || exit 1
done
grep -q '</html>' "$out" && ! grep -qE '\[[a-z_]+\]' "$out"

Leave only the final HTML and return its path, scope, collection time, and error window.

Thêm skills từ nvidia

accelerated-computing-cudf
nvidia
Hướng dẫn chính thức từ NVIDIA về NVIDIA cuDF GPU DataFrames, tăng tốc pandas, dask-cuDF, ETL, joins, groupby, I/O CSV/Parquet, ngữ nghĩa nullable, và…
accessibility
nvidia
Quy trình kiểm tra khả năng truy cập thống nhất trên phân tích tĩnh, kiểm thử thời gian chạy, các mẫu ARIA, điều hướng bàn phím và độ tương phản màu sắc. Sử dụng kỹ năng này…
accessing-mlflow
nvidia
Truy vấn và duyệt kết quả đánh giá được lưu trữ trong MLflow. Sử dụng khi người dùng muốn tra cứu các lần chạy theo ID lời gọi, so sánh chỉ số giữa các mô hình, lấy tạo phẩm…
add-binding-feature
nvidia
Thêm hoặc thay đổi bề mặt API NeMo Relay công khai trên toàn bộ runtime lõi và mọi binding bị ảnh hưởng
add-middleware
nvidia
Thêm một loại guardrail hoặc intercept mới vào pipeline middleware của NeMo Relay
aicr-analyzing-snapshots
nvidia
Sử dụng khi phân tích tệp YAML snapshot AICR, xem xét trạng thái cụm, so sánh đặc điểm nhà cung cấp, trích xuất thông tin chi tiết về cấu trúc liên kết GPU/mạng, hoặc…
aicr-auditing-docs
nvidia
Sử dụng khi rà soát tài liệu Markdown của AICR để tìm trùng lặp, sai lệch, cồng kềnh, và khoảng trống — nhằm giữ tài liệu có giá trị cao khi dự án phát triển. Kích hoạt khi "audit…
aicr-creating-guided-demos
nvidia
Tạo khung kịch bản demo có hướng dẫn tương tác (demos/*.sh), trực tiếp hoặc tự học, theo mẫu Frame → Tell → Show → Close. Kích hoạt khi có "demo script", "guided…